Xk3190-c801 Manual -

If you need assistance with a (e.g., how to configure a setpoint output, set up Modbus RTU, or resolve a particular error), please provide more details and I will give you a targeted solution.

| Command | Response | |---------|----------| | R | Return current gross weight (e.g., +00150.00 kg ) | | Z | Perform zero operation | | T | Tare current weight | | C | Clear tare | | S | Return stable status (0=unstable, 1=stable) | | P | Print current weight | | U | Switch unit | xk3190-c801 manual

Full parameter list is available in the original factory manual (over 50 settings). | Code | Meaning | Solution | |------|---------|----------| | E01 | A/D over range (negative) | Check load cell wiring; remove overload. | | E02 | A/D over range (positive) | Load cell signal too high; reduce load. | | E03 | Zero drift (>10% FS) | Calibrate zero; check load cell stability. | | E04 | EEPROM error | Replace EEPROM; restore defaults. | | E05 | Power-on zero out of range | Scale not empty at power-up; clear platform. | | E06 | Calibration error | Repeat calibration with correct weights. | | --- | Display freezes | Check power supply; reset via [Function] + [Zero] . | 9. Communication Commands (RS232) In command mode (F07=2), the indicator responds to ASCII commands ending with CR (0x0D). If you need assistance with a (e